Related Experiment Video
Updated: Aug 19, 2026

Instrumentation of Near-term Fetal Sheep for Multivariate Chronic Non-anesthetized Recordings
Published on: October 25, 2015
[Fetal pulse oximetry: a clinical methodological study]
The aim of the study is to provide preliminary assessment of the possibilities of fetal pulse oximetry as a method for monitoring of fetal pulse rate and oxygen saturation during labour. The study includes 65 pregnant women during active labour at term--all with one fetus and ruptured membranes. A system for fetal pulse oximetry is used, consisting of monitor Nellcor-N 400; oxygen sensor FS-14 and printer P-400 (Nellcor Puritan Bennett incorporation). Sensor is applied by mean dilatation of cervical channel 6.5 +/- 1.9 cm. Mean duration of monitoring of the pregnant woman is 104 +/- 68 minutes, range 30 to 180 min. The time of reliable signal quality is 83% for first stage of labour and 70% for second stage of labour. Mean SpO2 values are 47.1 +/- 9.8%. The conclusion is made that fetal pulse oximetry is an easy method to use, without side effects for mother and fetus. Mean SpO2 values are tower than in adults and vary inside wider range 35-55%.
The aim of the study is to provide preliminary assessment of the possibilities of fetal pulse oximetry as a method for monitoring of fetal pulse rate and oxygen saturation during labour. The study includes 65 pregnant women during active labour at term--all with one fetus and ruptured membranes. A system for fetal pulse oximetry is used, consisting of monitor Nellcor-N 400; oxygen sensor FS-14 and printer P-400 (Nellcor Puritan Bennett incorporation). Sensor is applied by mean dilatation of cervical channel 6.5 +/- 1.9 cm. Mean duration of monitoring of the pregnant woman is 104 +/- 68 minutes, range 30 to 180 min. The time of reliable signal quality is 83% for first stage of labour and 70% for second stage of labour. Mean SpO2 values are 47.1 +/- 9.8%. The conclusion is made that fetal pulse oximetry is an easy method to use, without side effects for mother and fetus. Mean SpO2 values are tower than in adults and vary inside wider range 35-55%.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...