External anions and volume-sensitive anion current in guinea-pig ventricular myocytes
Related Experiment Video
Updated: Oct 13, 2026

Study of the Functions and Activities of Neuronal K-Cl Co-Transporter KCC2 Using Western Blotting
Published on: December 9, 2022
1Department of Physiology and Biophysics, Dalhousie University, Halifax, NS, Canada.
Abstract:
The objective of this study was to determine the effects of anion replacement on volume-sensitive anion current in guinea-pig ventricular myocytes. Myocytes in the conventional whole-cell voltage-clamp configuration were superfused and dialysed with Na(+)-, K(+)-, and Ca(2+)-free solution, and exposed to external 75 mM Cl- solution of one-half normal osmolality. Prolonged exposures to hyposmotic solution promoted the development of outwardly-rectifying currents that were inactivated at high positive potentials and reversed in a Cl(-)-dependent manner (50 mV per decade pipette Cl- concentration). Replacement of external Cl- by iodide and aspartate affected the reversal potential (E(rev)) and slope conductance of the volume-sensitive current. Relative permeabilities calculated from changes in E(rev) were 1.49 +/- 0.09, 1.00, and 0.29 +/- 0.04 for iodide, Cl-, and aspartate, respectively; relative slope conductances between E(rev) and E(rev) + 40 mV were 1.21 +/- 0.09, 1.00, and 0.43 +/- 0.07, respectively. Replacement of Cl- also affected the time dependence of the volume-sensitive current; replacement by iodide reversibly enhanced the decay of outward current at positive potentials, whereas replacement by aspartate reduced it. These results are compared with earlier findings on noncardiac time- and voltage-dependent anion current activated by hyposmotic solution.
More Related Videos
08:11Voltage-Dependent Potassium Current Recording on H9c2 Cardiomyocytes via the Whole-Cell Patch-Clamp Technique
Published on: November 11, 2022
11:42Reconstitution of a Transmembrane Protein, the Voltage-gated Ion Channel, KvAP, into Giant Unilamellar Vesicles for Microscopy and Patch Clamp Studies
Published on: January 22, 2015
Related Concept Videos
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Non-gated Ion Channels
Compared to the gated ion channels, the non-gated channels, also known as leakage or passive channels, have no gating mechanism.
The Resting Membrane Potential
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow specific...