Balloon occlusion and transluminal aspiration of saphenous vein grafts to prevent distal embolization
Related Experiment Video
Updated: Jul 26, 2026

Vein Interposition Model: A Suitable Model to Study Bypass Graft Patency
Published on: January 15, 2017
B C Stein1, J Moses, P S Teirstein
1Division of Interventional Cardiology, Scripps Clinic, La Jolla, California 92037, USA. bcstein@yahoo.com
Insights
Distal embolization during saphenous vein graft interventions can cause myocardial infarction. A novel technique using balloon occlusion and aspiration prevented embolization, preserving blood flow.
Area of Science:
- Cardiovascular Interventions
- Interventional Cardiology
- Vascular Surgery
Background:
- Percutaneous interventions in saphenous vein grafts (SVGs) are prone to distal embolization.
- Distal embolization can lead to the no-reflow phenomenon and myocardial infarction.
- Effective prevention strategies are crucial for improving outcomes in SVG interventions.
Observation:
- A case is presented involving a patient undergoing percutaneous intervention in a saphenous vein graft.
- The distal portion of the SVG was occluded using a balloon catheter to prevent embolization.
- Percutaneous transluminal coronary angioplasty (PTCA) was performed after balloon occlusion.
Findings:
- The balloon occlusion successfully prevented distal embolization of particulate debris.
- Particulate debris was effectively aspirated using a Dorros/Probing catheter post-intervention.
- The no-reflow phenomenon was avoided, and myocardial infarction was prevented.
Implications:
- This technique offers a potential method to mitigate distal embolization during SVG interventions.
- Balloon occlusion combined with aspiration may improve safety and efficacy of PTCA in SVGs.
- Further studies are warranted to validate this approach in a larger patient cohort.
Abstract:
Distal embolization is a common complication of percutaneous intervention in saphenous vein grafts. This may lead to the "no reflow" phenomenon and subsequent myocardial infarction. We describe a case in which we occluded the distal portion of a saphenous vein graft with a balloon to prevent distal embolization, performed percutaneous transluminal coronary angioplasty, and then successfully aspirated the particulate debris with a Dorros/Probing catheter.
More Related Videos
09:04Synergizing Antegrade Endoscopic with Bridging Vein Harvesting for Improvement of Great Saphenous Vein Graft Quality from the Lower Leg
Published on: November 19, 2019
08:05Occlusion of the Great and Small Saphenous Vein Using Copolymeric Glue Based on N-Butyl Cyanoacrylate and Methacryloxy Sulfolane
Published on: December 9, 2022
Related Concept Videos
Peripheral Artery Disease V: Postoperative Nursing Management
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care