Related Experiment Video
Updated: Aug 12, 2026

Surgical Swine Model of Chronic Cardiac Ischemia Treated by Off-Pump Coronary Artery Bypass Graft Surgery
Published on: March 27, 2018
Left internal mammary artery graft perforation repair using polytetrafluoroethylene-covered stents
Abstract:
The increase in the use of the left internal mammary artery (LIMA) as graft of choice to the left anterior descending coronary artery for conventional and minimally invasive coronary artery bypass surgery has led to an increased incidence of LIMA pathologic lesions early after surgery. The lesion, commonly located in the body of the LIMA graft, is usually caused by mechanical injury during harvesting of the vessel. In this context, percutaneous intervention with stent implantation can be complicated by vessel rupture, which usually requires emergency surgical repair. We describe two cases of stent implantation in newly placed LIMA grafts complicated by vessel rupture, which were successfully repaired using polytetrafluoroethylene-covered stents.