High-performance liquid chromatographic analysis for the determination of domperidone in human plasma
1Department of Pharmacology, Pharmaceutical Research Institute, Warsaw, Poland.
Abstract:
A specific and sensitive high-performance liquid chromatographic method for the determination of domperidone in human plasma is described. Domperidone was isolated by solid-phase extraction using nitrile SPE cartridges. The drug was eluted with a mixture consisting of methanol-triethylamine-acetic acid, separated on a reversed-phase column, and measured by fluorimetric detection after post-column photoderivatization. The absolute extraction recovery from plasma samples was 83%. The limit of quantitation was established as 1 ng/ml. The relative standard deviation of the determination of plasma levels by this method over the standard curve concentration range was less than 10%, expect with the concentration of 1 ng/ml. The suitability of the method is shown for pharmacokinetic studies.