Related Experiment Video
Updated: Aug 10, 2026

Tracheotomy: A Method for Transplantation of Stem Cells to the Lung
Published on: February 25, 2007
Light-guided tracheal puncture for percutaneous tracheostomy
B M Addas1, W J Howes, O R Hung
1Department of Neurosurgery, Dalhousie University, Halifax, Nova Scotia, Canada.
Purpose:
To determine the effectiveness of lightwand-guided tracheal puncture for percutaneous tracheostomy.
Methods:
The desired puncture site was marked on the skin of the anterior neck. A lightwand (Trachlight) was inserted into the patient's endotracheal tube (ETT), so that the number indicator on the lightwand matched the number indicator of the ETT of the patient. At this position, the light bulb of the lightwand was exactly placed at the tip of the endotracheal tube. With the lightwand turned on, the lightwand together with the endotracheal tube (ETT-LW) was slowly withdrawn from the trachea until a bright glow in the anterior neck could be seen 1 cm above the marked puncture site. At this position, the tip of the ETT was 1 cm above the puncture site.
Results:
Percutaneous tracheostomy via a light-guided tracheal puncture was performed on 11 neurosurgical patients. The withdrawal of the endotracheal tube to a location above the puncture was accomplished easily with the lightwand. All percutaneous tracheostomies performed were successful, with ease and without any complications. The procedure time was 17.8 +/- 5.3 min. Mechanical ventilation was not interrupted during the whole procedure.
Conclusion:
The lightwand guided intratracheal puncture for percutaneous tracheostomy is a simple, effective, and safe procedure. This technique can avoid the risk of puncturing the endotracheal tube and/or cuff, thus allowing adequate ventilation and oxygenation during the percutaneous tracheostomy. Furthermore, this technique is inexpensive and minimizes the risk of damaging equipment like the fibreoptic bronchoscope.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Suctioning II: Procedure
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques