Related Experiment Video
Updated: Jul 28, 2026

06:53
Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−
Published on: July 27, 2018
Antideuteron yield at the AGS and coalescence implications
1Pennsylvania State University, University Park, Pennsylvania 16802, USA.
Physical Review Letters
|September 16, 2000
Summary
Experiment 864 measured invariant antideuteron yields in gold-platinum collisions. The findings provide insights into antimatter production and annihilation processes in high-energy nuclear physics.
Area of Science:
- Nuclear Physics
- Particle Physics
- High-Energy Physics
Background:
- Understanding antimatter production is crucial for testing the Standard Model.
- Heavy-ion collisions provide a unique environment to study the formation of exotic particles like antideuterons.
Purpose of the Study:
- To measure invariant antideuteron yields in 11.5A GeV/c gold-platinum collisions.
- To investigate the production mechanisms and coalescence parameters of antideuterons.
Main Methods:
- Analysis of 250x10^6 triggers from 14x10^9 central interactions in Experiment 864.
- Measurement of differential yields (1/2πp(t))d^2N/dydp(t) and the coalescence parameter B2.
Main Results:
- Invariant antideuteron yields were determined in specific rapidity (y) and transverse momentum (p(t)) ranges.
- A coalescence parameter B2 of 4.1+/-2.9(stat)+2.3-2.4(syst)x10^-3 GeV^2c^-3 was found.
Conclusions:
- The measured yields and coalescence parameter offer insights into antideuteron formation.
- Results have implications for understanding antimatter annihilation and nuclear matter at extreme conditions.
Related Concept Videos
Nuclear Transmutation
Nuclear transmutation is the conversion of one nuclide into another. It can occur by the radioactive decay of a nucleus, or the reaction of a nucleus with another particle. The first manmade nucleus was produced in Ernest Rutherford’s laboratory in 1919 by a transmutation reaction, the bombardment of one type of nuclei with other nuclei or with neutrons. Rutherford bombarded nitrogen-14 atoms with high-speed α particles from a natural radioactive isotope of radium and observed protons being...
Mass Spectrometry of Amines
In mass spectroscopy, amines undergo fragmentation to give parent ions with odd molecule weights. This observed mass spectrum follows the nitrogen rule; a molecule with an odd number of nitrogen atoms produces a molecular ion with an odd molecular weight. Amines undergo fragmentation through α cleavage, producing nitrogen-containing cations—iminium ions—and alkyl radicals. Mass spectra of aromatic and cyclic aliphatic amines exhibit strong molecular ion peaks, but acyclic aliphatic amines show...
¹³C NMR: ¹H–¹³C Decoupling
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Mass Analyzers: Overview
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Mass Analyzers: Common Types
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Tandem Mass Spectrometry
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...

