Related Experiment Video
Updated: Jul 29, 2026

Laboratory Estimation of Net Trophic Transfer Efficiencies of PCB Congeners to Lake Trout (Salvelinus namaycush) from Its Prey
Published on: August 29, 2014
Routine analysis of 101 polychlorinated biphenyl congeners in human serum by parallel dual-column gas chromatography
A P DeCaprio1, A M Tarbell, A Bott
1School of Public Health, The University at Albany, State University of New York, Rensselaer 12144, USA.
Abstract:
Polychlorinated biphenyl (PCB) exposure has been linked to a variety of toxic effects in animal experiments and in certain human case reports and epidemiologic studies. A total of 209 individual PCB congeners are possible, based on chlorination level and ring substitution pattern. Commercial PCBs are a complex mixture of congeners, and over 75 of these have been reported to be present in human tissues at widely varying levels. Because the biologic activity of individual PCBs is a function of extent and pattern of chlorine substitution, "congener-specific" PCB analysis of human tissue has gained increasing importance in assessing possible links between PCB exposure and toxic effects. A high-sensitivity analytical method using dual-column gas chromatography (GC) with electron capture detection (ECD) for determining 101 PCB congeners (83 individual, 18 as pairs/triplets) plus 1,1-dichloro-2,2-bis(p-chlorophenyl)ethylene (p,p'-DDE), hexachlorobenzene (HCB), and mirex, in human serum is described. Separation is performed concurrently on parallel-configured DB-5 and Apiezon-L capillary columns. The current method is a modification of previously reported dual-column GC-ECD systems with improvements to the extraction and analytical protocols and the implementation of a comprehensive QA/QC program. The method employs two surrogate standards (PCBs IUPAC 125 and 192) and internal standard (IUPAC 104)-based quantitation, in addition to per-batch check standards and method blanks. Although optimized for serum, the method is applicable to all human, experimental animal, and environmental biota samples. The accuracy, precision, and reliability of the method were assessed using a variety of QA/QC endpoints. Finally, the use of the method in determining level and prevalence of PCB congeners in a cohort of adult Native-American individuals with historical environmental PCB exposure is reported.
More Related Videos
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors