A non-contact vital signs monitor
G Matthews1, B Sudduth, M Burrow
1Biomedical Interactive Technology Center, Georgia Institute of Technology, Atlanta, GA 30318, USA.
Abstract:
The expansion and contraction of the lungs and heart result in movement of the chest wall that can be detected and monitored to determine respiration and heart rate. A prototype non-contact Vital Signs Monitor (VSM) has been developed which uses very low power, high frequency Doppler radar to detect these motions. Digital signal processing (DSP) techniques, imbedded in the VSM, are used to extract heart and respiration rate information from the resultant waveform. A 10-GHz prototype VSM was developed for the Air Force in the mid-1980s using analog technology. The objective was to assess a fallen soldier's clinical condition at distances up to 100 meters before committing resources to assist that individual. An updated and improved version of the original VSM was developed in 1997. This device was designed to operate at shorter distances, use a higher frequency carrier, and provide more specific heart and respiration rate information using digital signal processing techniques. The VSM radar system is a straightforward homodyne receiver. It operates using frequency modulated continuous wave (FM-CW) transmission, which allows for very low power levels. The safe human power density exposure level at its operating frequency of 35 GHz is 10 mW/cm2. A simple approximation using uniform distribution and an antenna aperture of 2 cm by 3 cm gives a power density at the antenna face of 0.017 mW/cm2, nearly a factor of 1000 below the safe level. When the VSM's antenna is trained on the chest wall of a subject, the VSM is capable of measuring and distinguishing minute movements resulting from the mechanical activity of the heart and lungs. As the subject's chest wall moves, the exact phase of the return signal changes. To avoid the possibility of phase-related dead spots, two signals differing in phase by 90 degrees are used to demodulate the signal to baseband (DC). The two resulting "time-varying DC" signals represent the sine and cosine of a phase angle corresponding to the changing position of the target, in this case the motion of the chest wall. The current VSM operates at a frequency of 35 GHz with a corresponding wavelength of only 8.6 mm. This provides a response sensitive enough to detect the small motions caused by cardiac function. The Vital Signs Monitor has several possible application areas. The fact that it is noncontacting would make it especially attractive for monitoring patients in burn units, NICUs, or trauma centers, where attaching electrodes is either inconvenient or not feasible. Results to date indicate a strong correlation between the cardiac component of the motion signal and an electrocardiogram (ECG). With careful signal processing and analysis, it may be possible to extract clinically useful information about cardiac condition, function, or performance from the surface-motion waveform. This could provide a safe, inexpensive, and painless addition to the diagnostic and monitoring tools currently available to cardiologists. Although there are technical obstacles to overcome in filtering gross motions of the subject, the VSM offers significant advances over conventional methods of measuring heart and respiration rate.
Related Concept Videos
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes or...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Holter Monitor: 24-Hour Monitoring