Digital radiography using an EBCCD-based imaging device

Rossi1, Casali, Golovkin

  • 1Physics Department, University of Bologna and I.N.F.N., Italy. rossim@bo.infn.it

Applied Radiation and Isotopes : Including Data, Instrumentation and Methods for Use in Agriculture, Industry and Medicine
|September 26, 2000
PubMed
Summary

Electron-bombarded charge-coupled devices (EBCCD) offer a promising solution for dose reduction in medical imaging and specialized applications like industrial X-ray imaging. This study presents a prototype EBCCD system for digital radiography and computed tomography.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

M. Rossi's Case of Recovery after Extirpation of the Uterus Immediately after Delivery.

Medical examiner (Philadelphia, Pa.)·2023
Same author

Memoir on the Loss of the Teeth.

The American journal of dental science·2019
Same author

Memoir on the Loss of the Teeth.

The American journal of dental science·2019
Same author

Inhibitory action on GHRH-induced GH secretion of chronic tamoxifen treatment in breast cancer.

Clinical endocrinology·2017
Same author

Case Of True Malignant Pemphigus.

Revista chilena de pediatria·2010
Same author

Mitral valve repair. Quadrangular resection of the posterior leaflet in patients with myxomatous degeneration.

Arquivos brasileiros de cardiologia·2001

Area of Science:

  • Medical Imaging
  • Applied Physics
  • Industrial Nondestructive Testing

Background:

  • Intensified imaging systems are crucial for reducing patient radiation dose in medical radiography.
  • Electron-bombarded charge-coupled devices (EBCCD) show potential for diverse applications, including low-light imaging and particle tracking.
  • Traditional imaging methods face limitations in dose reduction and specialized imaging scenarios.

Purpose of the Study:

  • To develop and test a prototype EBCCD image-intensifier tube for X-ray digital radiography (DR) and computed tomography (CT).
  • To evaluate the feasibility of EBCCD technology for industrial X-ray imaging applications.
  • To assess the performance of the EBCCD device in analyzing industrial components.

Main Methods:

  • Development of a prototype EBCCD image-intensifier tube.

Related Experiment Videos

  • Implementation of the EBCCD tube in X-ray digital radiography (DR) setups.
  • Analysis of industrial components using the developed EBCCD-based DR system.
  • Testing and performance evaluation of the EBCCD device.
  • Main Results:

    • The prototype EBCCD image-intensifier tube demonstrated suitability for X-ray DR and CT applications.
    • Successful DR analysis of industrial components was achieved using the EBCCD device.
    • The EBCCD technology shows promise for specialized industrial imaging needs.

    Conclusions:

    • EBCCD technology presents a viable option for advanced X-ray imaging in both medical and industrial fields.
    • The developed prototype is a significant step towards practical EBCCD applications in digital radiography and computed tomography.
    • Further research can optimize EBCCD systems for enhanced performance and broader industrial adoption.