Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Comprehensive two-dimensional gas chromatography via differential flow modulation
1Department of Chemistry, Oakland University, Rochester, Michigan 48309-4477, USA.
Abstract:
A novel comprehensive two-dimensional gas chromatograph has been developed that utilizes differential flow modulation. This technique uses a 6-port valve to collect effluent from a primary column and periodically inject the effluent into a secondary column. The flow in the secondary column is kept 20 times larger than the flow in the primary column so the contents of the sample loop can be flushed into the secondary column in 5% of the collection time. Peaks widths at half-maximum of approximately 0.06 s are generated for a 1.0 Hz secondary injection frequency. Sensitivity is not compromised, as 80% of the sample passes through both columns and reaches the detector. This simple yet effective technique has been used to analyze mixtures of alkanes, alkenes, aldehydes, alcohols, aromatics, esters, and ketones with high speed and high resolution.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II