Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 30, 2011
An assessment of quality control testing in an emergency department (ED) maintained arterial blood gas analyzer
O'Shaughnessy1, Emancipater, Hsu
1Beth Israel Medical Center, New York, NY.
Abstract:
Emergency medicine by its nature requires the immediacy of laboratory testing. Point of care testing (POCT) affords the ED the fastest access to important laboratory data. To the best of the authors' knowledge, maintenance of an arterial blood gas (ABG) analyzer as a POCT device by ED personnel has not been studied. OBJECTIVE: To determine the accuracy of POCT quality control testing of an ED maintained ABG Analyzer (Gem Premier)-Instrumentation Laboratory). METHODS: We compared comprehensive quality control data obtained when the ABG analyzer was maintained by the Department of Clinical Laboratories with data obtained from the same analyzer when it was maintained by ED attending physicians. Each parameter measured by the ABG analyzer was tested using unknown control samples supplied by the College of American Pathologists. These two groups of data were then compared to the total number of obtained values submitted to the College of American Pathologists. RESULTS: Each parameter measured (n = 7) showed no difference between the two groups in regard to overall pass rate. All values for the two groups fell within the limits of acceptability when compared to all other samples analyzed by the College of American Pathologists (range 159-208 other labs). CONCLUSIONS: ED attendings are capable of quality control maintenance of an ABG analyzer as a POCT device under the quality control testing parameters set forth by the College of American Pathologists.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality Assurance
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...