Analysis of urine for drugs of abuse using mixed-mode solid-phase extraction and gas chromatography-mass spectrometry
S Paterson1, R Cordero, S McCulloch
1Toxicology Unit, Imperial College School of Medicine, London, UK. s.paterson@ic.ac.uk
Abstract:
A method for the simultaneous analysis of urine for the major drugs of abuse is described. The analytical procedure uses solid-phase extraction (SPE), gas chromatography-mass spectrometry (GC-MS) and a semi-automated identification process. It allows simultaneous extraction, derivatization and analysis of acidic, neutral and basic drugs from urine. Urine samples were subjected to enzymatic hydrolysis followed by SPE using Bakerbond narc-2 columns. The eluant was selectively derivatized with N-methyl-bis-trifluoroacetamide (MBTFA) and N-methyl-N-trimethylsilyltrifluoroacetamide + 1% trimethylchlorosilane. Analysis was performed using a GC-MS system operating in full scan mode. A simple macro programme was written to enhance the mass spectra identification capabilities of the MS software by producing extracted ion chromatograms (EIC) for the drugs of interest. Once a suspect compound was indicated by EIC, the mass spectrum of the compound was searched manually against reference libraries for positive identification and the retention time checked against that of the standard. This procedure has increased both the amount and the reliability of information given to clinicians without increasing the cost per sample. The system has been in routine operation for 24 months, processing up to 40 urine samples per day, with a usual turn-around time of 48 h.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography