Related Experiment Video
Updated: Aug 19, 2026

The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Evaluation of a novel, rapid-acting, sterilizing solution at room temperature
1Pharmaceutical Sciences, Research and Development, Healthpoint, Ltd, San Antonio, TX 78215, USA.
Abstract:
Test data are presented for a novel chemical germicide formulation capable of sterilizing reusable medical devices in 30 minutes at 20 degrees C in an open tray. The tests conducted with this rapid-acting sterilizing solution (RSS) included sporicidal, mycobactericidal, and virucidal studies performed in accordance with Association of Official Analytical Chemist International or Environmental Protection Agency published guidelines, by using RSS stressed for as long as 7 days. Sporicidal assays were performed at 20 degrees C with a 30-minute exposure time by using both Clostridium sporogenes and Bacillus subtilis spores dried on porcelain penicylinders or suture loops (n = 60 carriers per treatment). For comparison, identical carriers were exposed to a commercial glutaraldehyde-based sterilizing solution stressed to a maximum-use time of 14 days and exposed per manufacturer's requirements (10 hours at 25 degrees C). The RSS sterilized 100% of the carriers of both spore types. The glutaraldehyde solution demonstrated 100% sterilization of C sporogenes -treated carriers but had difficulty sterilizing B subtilis spore-laden carriers (ie, no sterilization of suture loops and only 57% sterilization of porcelain penicylinders). Similarly, Mycobacteria bovis and selected fungal and viral agents were exposed to stressed solution for 5 minutes or less at 20 degrees C. In each case, the resulting log decrease in viable microorganisms significantly supported a claim for rapid high-level disinfection. Based on these data, RSS demonstrates high-level disinfection in 5 minutes and sterilization in 30 minutes at 20 degrees C.
Related Concept Videos
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration

