Time-resolved cryogenic modulation for targeted multidimensional capillary gas chromatography analysis
Related Experiment Video
Updated: Oct 11, 2026

Cryogenic Sample Loading into a Magic Angle Spinning Nuclear Magnetic Resonance Spectrometer that Preserves Cellular Viability
Published on: September 1, 2020
P J Marriott1, R C Ong, R M Kinghorn
1Department of Applied Chemistry, Royal Melbourne Institute of Technology, Victoria, Australia. philip.marriott@rmit.edu.au
Abstract:
Multidimensional gas chromatography (MDGC) is performed in a new manner, described in this paper. The method incorporates two directly coupled columns and employs a longitudinally modulated cryogenic trap located between the columns. No heartcutting process is used, but rather a method better termed selected zone compression pulsing is used. Compared with normal MDGC, where primary column effluent has to be temporarily diverted either to a monitor detector or to the second dimension column, the new procedure in its simplest mode passes all of the first column effluent to the second column. It is simply the times at which the modulation of the trap is performed that determines which target solutes will be selected for enhanced separation. This approach allows almost instantaneous separation of selected zones on the second column, and has the potential to significantly simplify the MDGC method. Since data are presented in a time-response format, and do not require transformation as previously described for comprehensive GC when using the longitudinal modulator, quantitation and report generation are essentially the same as in any GC method and data system. Advantages also include significant sensitivity improvement. By using cryofocussing, and benefiting from the zone compression effects along with fast GC conditions on the second dimension, new possibilities for MDGC can be realised. The method is demonstrated by using a mixture of semi-volatile aromatic hydrocarbons.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...