Analytical method for the determination of atrazine and its dealkylated chlorotriazine metabolites in water using gas
1Development Resources/Chemical Support Department, Novartis Crop Protection, Inc., Greensboro, North Carolina 27419, USA.
Abstract:
A multiresidue method is reported for the determination of atrazine and its dealkylated chlorotriazine metabolites in water. Water samples are buffered to pH 10 and partitioned in ethyl acetate. Final analysis is accomplished using gas chromatography/mass selective detection (GC/MSD) in the selected ion monitoring (SIM) mode. The limit of detection (LOD) is 0.050 ng and the limit of quantification (LOQ) is 0.10 ppb for 2-chloro-4-(ethylamino)-6-(isopropylamino)-s-triazine (atrazine), 2-amino-4-chloro-6-(isopropylamino)-s-triazine (G-30033), 2-amino-4-chloro-6-(ethylamino)-s-triazine (G-28279), and 2, 4-diamino-6-chloro-s-triazine (G-28273). The mean procedural recoveries were 90, 92, 98, and 85% and the standard deviations were 12, 13, 16, and 20% for atrazine, G-30033, G-28279, and G-28273, respectively (n = 30). The study was conducted under U.S. EPA FIFRA Good Laboratory Practice Guidelines 40 CFR 160 for method validation. The reported procedure accounts for residues of G-28273 in water that are not included in EPA Method 507.
More Related Videos
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
04:19An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors