Related Experiment Video
Updated: Jul 21, 2026

A New Straightforward Method for Lipophilicity (logP) Measurement using 19F NMR Spectroscopy
Published on: January 30, 2019
Measurement of dilute 29Si species in solution using a large volume coil and DEFT NMR
1Department of Chemical Engineering, University of California, Santa Barbara 93106, USA.
Abstract:
A large-sample-volume nuclear magnetic resonance (NMR) spectroscopy probehead has been developed for the detection and characterization of low concentrations of 29Si species in aqueous solution. The approach described entails the use of a large-diameter radio frequency solenoid coil that permits substantially larger sample volumes to be investigated at moderate magnetic field strengths, compared with conventional NMR probehead configurations. In addition, difficulties presented by long 29Si T1 relaxation times have been circumvented by using the DEFT NMR pulse sequence, which permits more rapid signal averaging. Through a combination of these hardware and methodological improvements, high-resolution 29Si NMR spectra have been obtained at 4.2 T (29Si resonance frequency = 36.8 MHz) for an 800 microM solution of 96% 29Si-enriched silicic acid, H4SiO4 (pH approximately 8), with a signal-to-noise ratio of 16 and a line width of 31 Hz after 3 h of total measurement time.
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
NMR Spectrometers: Resolution and Error Correction
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a high...