Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Assessment of the otolith-autonomic response using spectral analysis of the R-R interval and blood pressure
K I Yamamoto1, Y Kawasaki, R Izumi
1Department of Otolaryngology and Sensory Organ Surgery, Osaka University, Graduate School of Medicine, Tokyo, Japan.
Abstract:
The effects of otolith stimulation on systolic blood pressure (SBP) and R-R interval fluctuations were investigated in 12 healthy subjects and 5 patients with loss of labyrinthine function. The vestibular otolith organs were stimulated by centrifugal forces, the constant rotation of a chair fixed outside of the rotation axis on the horizontal plane. The chair was fixed along the direction of centrifugal force (eccentric rotation [ECR]) or along the tangent line (eccentric lateral rotation [ECLR]). The ECR stimulates both the utricular and saccular maculae, whereas the ECLR stimulates only the utricular maculae. Spectral analysis showed that in the healthy subjects, low-frequency SBP increased significantly during ECR but not during ECLR. There was no significant increase in low-frequency SBP in patients with labyrinthine loss. In the R-R interval analysis, however, the low- and high-frequency components did not change significantly in the healthy subjects during ECR. Our findings indicate that stimulation of the otolith maculae, especially the saccular organs, predominantly produces augmentation of the alpha-sympathetic activities rather than cardiac sympathovagal outflow to the heart.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equilibrium and Balance
Measurement of Blood Pressure