Flow dynamics of stenotic aortic valves assessed by signal processing of Doppler spectrograms
J Bermejo1, J C Antoranz, M A García-Fernández
1Department of Cardiology, Hospital General Universitario Gregorio Marañón, Universidad Complutense de Madrid, Spain. javbermejo@jet.es
Abstract:
Clinical assessment of aortic stenosis (AS) is sometimes challenging, because all hemodynamic indexes of severity are modified by flow rate. However, the mechanisms underlying flow dependence remain controversial. Analysis of instantaneous flow dynamics has provided crucial information in a number of cardiovascular disorders and may add new insight into this phenomenon. This study was designed to analyze in vivo the effects of flow interventions on instantaneous valvular dynamics of stenotic valves. For this purpose, a custom algorithm for signal processing of Doppler spectrograms was developed and validated against a control population. Digital Doppler recordings at the aortic valve and left ventricular outflow tract were obtained in 15 patients with AS, at baseline and during low-dose dobutamine infusion; 10 normal subjects were studied as controls. Spectrograms were processed by signal averaging, time alignment, modal-velocity enhancement, envelope tracing, and numerical interpolation. Instantaneous relative aortic valve area (rAVA) was obtained by the continuity equation and plotted against normalized ejection time. Curves were classified as either type A (rapid, early-systolic opening) or type B (slow, end-systolic opening). Curves from controls closely matched prior knowledge of normal valve dynamics, but curves from patients were clearly different: all controls except 2 (80%) had type A, whereas all patients except 3 (80%) had a type B pattern (p = 0.03). Dobutamine infusion in patients increased and slightly anticipated peak rAVA by accelerating valve opening. Despite similar values of area and pressure difference, type B dynamics were associated with lower blood pressure (p = 0.01) and worse long-term outcome (>3 years) than type A flow dynamics (p = 0.02). Signal processing of Doppler spectrograms allows a comprehensive assessment of aortic flow dynamics. Differences in timing of valve aperture and in maximal leaflet excursion account for flow-mediated changes in valve area, suggesting complementary effects of inertia and elasticity on the kinetics of stenotic aortic valves. Flow-dynamic analysis provides novel clinical information regarding physiology of AS unavailable to conventional indexes.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Mitral Stenosis II: Clinical features and Diagnostic Tests