Intracavitary contrast intensity after transpulmonary transmission of a second-generation contrast agent at normal
C A Greim1, J A Broscheit, K W Lorenz
1Department of Anesthesiology, Julius-Maximilians-Universität, Würzburg, Germany.
Abstract:
In this closed-chest preparation in 10 anesthetized pigs, we determined the effects of left ventricular (LV) contractility changes on the echocardiographic contrast intensity variation of a second-generation contrast agent within the LV cavity. The peak positive rate of change in LV pressure (dP/dt(max)), as an index of the isovolumetric phase, was gradually reduced by administration of halothane and propranolol, and the velocity of circumferential fiber shortening (Vcfs) was referenced as an index for the LV ejection phase. Contrast intensity-time curves of the LV cavity were obtained after transpulmonary transmission of the contrast agent. An off-line densitometric method was performed to determine peak maximum and minimum intensities (I(max), I(min)) and their difference (I(amp)). Compared with baseline values, at reductions in dP/dt(max) of 50% and 75%, the contrast intensity parameters I(max), I(min), and I(amp) were decreased by 23% +/- 6% and 44% +/- 5%, 24% +/- 5% and 44% +/- 3%, and 31% +/- 6% and 45% +/- 3%, respectively (P <.05). Significant correlations were observed between I(amp) and dp/dt(max) (r = 0.82, P <.003, n = 30) and their changes (r = 0.59, P <.03, n = 20), but correlations between contrast indexes and Vcfs were only moderate. The sensitivity of I(amp) to indicate changes in dP/dt(max) and Vcfs was 0.95 and 0.83, respectively. The cyclic variation of LV intracavitary contrast intensity reflects the isovolumetric contraction phase better than the ejection phase. The results suggest that measurements of cyclic intensity changes may contribute to the assessment of myocardial contractility changes. Underlying biophysical mechanisms and load dependency of this phenomenon require further investigation.
More Related Videos
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...