Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Automated ultrasonic measurement of human arteries for the determination of endothelial function
1Medizinische Klinik B, Klinik für Kardiologie, Pneumologie, Angiologie, Heinrich-Heine-Universität Düsseldorf. preikm@uni-duesseldorf.de
Aim:
Brachial artery ultrasonography is used to measure flow-mediated dilatation (FMD) as a marker of endothelial function in patients at risk for atherosclerosis. Major disadvantages are the time-consuming manual readings and the high within- and between-observer variability. The authors hypothesize that the ultrasound-based determination of endothelial function can be simplified and refined by an automated analysis system.
Methods And Results:
FMD was quantified by a 7.5 MHz linear transducer following 5 minutes of ischemia of the proximal forearm in 8 healthy volunteers on two occasions. Brachial artery diameter was comparatively assessed 1. manually from the video signal and 2. by a PC-based analyzing system. For the manual readings the mean differences for the FMD were 2.5 +/- 2.3% between-reader, 2.0 +/- 0.9% within-reader and 2.1 +/- 1.5% for scans on different days in contrast to 0.8 +/- 0.4 (between-reader), 0.8 +/- 0.6 (within-reader) and 1.3 +/- 0.9% (day-to-day) for the computerized system. The coefficient of variability for the measurement of arterial diameter was 1.34% for manual readings and 0.78% for the automated analysis system. The mean time for manual readings from S-VHS tapes was 35 minutes in contrast to 9 minutes for the PC-based analysis system.
Conclusions:
The new automated analysis system for the boundary detection of the vascular wall reduces the variability and greatly increases the speed of the measurements to determine endothelial function. In future, these advantages will help to screen larger numbers of individuals for endothelial dysfunction, particularly for follow-up and intervention trials, and to reduce the variability between different laboratories.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement