Related Experiment Video
Updated: Jul 22, 2026

Performing Intracochlear Electrocochleography During Cochlear Implantation
Published on: March 8, 2022
Shaw scalpel in revision cochlear implant surgery
J T Roland1, A J Fishman, S B Waltzman
1Department of Otolaryngology, New York University School of Medicine, New York, USA.
The Shaw scalpel offers a safe alternative to electrocautery in cochlear implant surgeries, preventing device damage and ensuring good wound healing. This method allows for accurate analysis of explanted devices and maintains patient speech understanding.
Area of Science:
- Otolaryngology
- Neurosurgery
- Surgical Innovation
Background:
- Electrocautery use is restricted in cochlear implant revision/replacement surgery due to risks of tissue damage and interference with device failure analysis.
- The Shaw scalpel, a thermally activated blade, offers hemostasis and has demonstrated utility in various surgical fields.
- Minimizing wound and flap complications is critical in cochlear implant procedures.
Purpose of the Study:
- To evaluate the safety and efficacy of the Shaw scalpel in revision and primary cochlear implant surgeries.
- To assess wound healing, alopecia, and speech outcomes when using the Shaw scalpel.
- To determine if the Shaw scalpel preserves the integrity of explanted cochlear devices for diagnostic purposes.
Main Methods:
- Retrospective review of 22 cochlear implant surgeries (revision and primary) utilizing the Shaw scalpel.
- Data collection included patient demographics, surgical indications, reasons for electrocautery contraindication, and intraoperative notes.
- Postoperative evaluation focused on wound healing, alopecia, and speech recognition testing.
Main Results:
- No significant intraoperative complications were observed with Shaw scalpel use.
- Long-term wound healing outcomes were comparable to conventional surgical techniques.
- Explanted devices remained undamaged, facilitating accurate cause-of-failure analysis.
- All patients maintained or improved their preoperative speech recognition levels.
Conclusions:
- The Shaw scalpel is a safe, effective, and user-friendly instrument for cochlear implant surgery, particularly when electrocautery is contraindicated.
- It minimizes risks associated with electrocautery, such as end-organ damage and interference with device diagnostics.
- The technique supports favorable wound healing and preserves patient auditory outcomes.
More Related Videos
06:54Performing Repeated Intraoperative Impedance Telemetry Measurements during Cochlear Implantation
Published on: August 4, 2023
03:49Enhanced Cochlear Coverage and Hearing Preservation in High-Frequency Hearing Loss via Electric Acoustic Stimulation with Longer Electrode
Published on: October 11, 2024