Related Experiment Videos
Case report: galactography-guided wire localization of an intraductal papilloma
J S Chow1, D N Smith, C M Kaelin
1Department of Radiology, Brigham and Women's Hospital, 75 Francis Street, Boston, MA 02115, USA.
Abstract:
Galactography is used to evaluate spontaneous unilateral nipple discharge by catheterization of the duct orifice and instillation of radiopaque contrast material. The most common cause of a bloody discharge is an intraductal papilloma which appears as a smooth lobulated intraluminal filling defect or a solitary obstructed duct on galactography. Carcinomas may be the cause of up to 13% [1] of abnormal nipple discharge and cannot be reliably distinguished from papillomas at galactography. Thus any intraductal filling defect or irregularity in symptomatic patients should be surgically evaluated to obtain a tissue diagnosis. Unfortunately, the histologic examination of the biopsy specimen does not always identify the lesion seen at galactography [2]. A potentially more reliable method of locating lesions identified on galactography is described. Chow, J. S. (2001). Clinical Radiology56, 72-73.