Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Arterial pressure measurements using infrared photosensors: comparison with CW Doppler
1Noninvasive Vascular Laboratory, Department of Radiology, St Joseph Mercy Hospital, 44405 Woodward Avenue, Pontiac, Michigan 48341, USA.
Abstract:
We evaluated the accuracy of modern infrared photosensors (IPs) from a photoplethysmography (PPG) machine as flow detector in determining the systolic arterial pressures and ankle/brachial indices (ABIs) in comparison to the traditional continuous wave Doppler (Doppler) method. Pressures were obtained by placing an appropriate pneumatic cuff above the elbow and ankle. The Doppler probe was placed at brachial artery, posterior tibial artery and dorsalis pedis artery, and the IP was placed on the pad of the index finger and great toe. The two techniques were compared in 181 limbs in our non-invasive vascular laboratory, 133 limbs with normal and 48 limbs with abnormal ABIs. The accuracy of absolute ankle pressure measurements was also compared by both methods. We found that IPs from PPG machine have a good correlation (linear regression r=0.96 for normal and r=0.95 for abnormal ankle pressures) with the Doppler method. There was no significant difference (P< or =0.0001) in the ABIs calculated by two methods in either normal or abnormal subjects. The PPG method was easier, quicker and automated as compared with the cumbersome Doppler method. While PPG method does not differentiate between occlusive disease of posterior tibial and anterior tibial/dorsalis pedis arteries, it is better suited for non-compliant patients and is superior to Doppler method in advanced occlusive arterial disease. We recommend that it be used on a routine basis.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: