Variability of leptin values measured from different sample matrices.

M Gröschl1, R Wagner, H G Dörr

  • 1Klinik mit Poliklinik für Kinder und Jugendliche, Friedrich-Alexander-Universität Erlangen-Nürnberg, Loschgestrasse 15, D-91054 Erlangen, Germany. michael_groeschl@hotmail.com

Hormone Research
|February 22, 2001
PubMed
Summary

For accurate leptin measurement, K2-EDTA or lithium-heparin plasma is recommended over serum. Citrate plasma shows lower leptin values due to dilution effects.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Diagnostics, clinical aspects and genetics of congenital corneal opacities].

Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft·2022
Same author

Use of an ultrasound cell retention system for the size fractionation of somatic embryos of woody species.

Plant cell reports·2019
Same author

Exercise during pregnancy and its impact on mothers and offspring in humans and mice.

Journal of developmental origins of health and disease·2017
Same author

Experts' Opinion on the Prenatal Therapy of Congenital Adrenal Hyperplasia (CAH) Due to 21-Hydroxylase Deficiency - Guideline of DGKED in cooperation with DGGG (S1-Level, AWMF Registry No. 174/013, July 2015).

Geburtshilfe und Frauenheilkunde·2017
Same author

Therapeutic monitoring of immunosuppressive drugs in pediatric patients: special considerations.

Expert review of clinical pharmacology·2016
Same author

[Cologne Statement for Medical Care of Refugees].

Gesundheitswesen (Bundesverband der Arzte des Offentlichen Gesundheitsdienstes (Germany))·2016

Area of Science:

  • Biochemistry
  • Clinical Chemistry
  • Endocrinology

Background:

  • Leptin measurements are crucial for understanding metabolic and endocrine functions.
  • Standard laboratory practice typically involves analyzing leptin in serum or EDTA-plasma.

Purpose of the Study:

  • To compare the precision and accuracy of leptin quantification across different blood sample matrices.
  • To identify the optimal sample type for reliable leptin level determination.

Main Methods:

  • Blood samples from healthy volunteers were processed into serum and plasma using K2-EDTA, citrate, fluoride, or lithium-heparin.
  • Leptin concentrations were measured using a specific radioimmunoassay.
  • Statistical analysis was performed to compare results between matrices.

Related Experiment Videos

Main Results:

  • Serum samples exhibited the highest coefficient of variation (CV: 11.9%), while K2-EDTA plasma showed very low CV (5.3%).
  • Leptin levels were significantly lower in serum compared to K2-EDTA plasma (p < 0.05).
  • Fluoride and lithium-heparin plasma yielded the lowest CVs (5.2% and similar to K2-EDTA, respectively), whereas citrate plasma showed lower values (~25% less) and a higher CV (5.8%).

Conclusions:

  • K2-EDTA and lithium-heparin plasma provide the most reliable and precise matrices for leptin measurement.
  • Citrate plasma may lead to underestimated leptin concentrations due to dilution by anticoagulants.
  • The study recommends using K2-EDTA or lithium-heparin plasma for accurate leptin quantification.