Related Experiment Video
Updated: Aug 5, 2026

05:22
Iris Fixation via External Pentagram Suturing
Published on: May 5, 2022
Intraorbital bamboo foreign body in a chronic stage: case report
1The Medical Centre Leeuwarden, The Netherlands.
International Journal of Oral and Maxillofacial Surgery
|February 24, 2001
Summary
A chronic intra-orbital bamboo foreign body case highlights the need for advanced imaging. Three-dimensional computed tomography aids in selecting the best surgical method for foreign body removal.
Area of Science:
- Ophthalmology
- Radiology
- Surgical Case Reports
Background:
- Orbital foreign bodies can present with delayed symptoms.
- Chronic foreign bodies pose unique diagnostic and management challenges.
Observation:
- A case of a long-standing bamboo foreign body within the orbit is described.
- The foreign body was lodged in a chronic stage, presenting subtle initial symptoms.
Findings:
- Radiological examination, specifically three-dimensional computed tomography (3D-CT), was crucial for precise localization.
- 3D-CT provided detailed anatomical information essential for surgical planning.
Implications:
- This case underscores the importance of comprehensive radiological assessment for intra-orbital foreign bodies.
- Advanced imaging techniques like 3D-CT are vital for determining optimal surgical strategies and improving patient outcomes.