Flow injection potentiometric determination of pipazethate hydrochloride

N T Abdel-Ghani1, A F Shoukry, R M el Nashar

  • 1Chemistry Department, Faculty of Science, Cairo University, Giza, Egypt.

The Analyst
|February 24, 2001
PubMed

Related Concept Videos

Potentiometry: Overview01:06

Potentiometry: Overview

Potentiometry is an analytical technique that measures the potential difference between two electrodes in an electrochemical cell without drawing any significant current that could alter the solution's composition. This method employs an indicator electrode, which exchanges electrons with the analyte solution, and a reference electrode with a constant potential. Each electrode is immersed in a solution comprised of two half-cells. In a conventional setup, the reference electrode serves as the...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Potentiometric Titration: Overview01:31

Potentiometric Titration: Overview

Potentiometric titration is a quantitative analytical technique that determines the concentration of an analyte by measuring the potential difference between the two electrodes in the solution. The endpoint of a potentiometric titration is the point at which there is a significant change in the potential difference. It occurs when the stoichiometric reaction between the analyte and the titrant is complete. The endpoint is usually determined graphically by plotting the measured potential...
Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...