Abstract:
An attempt was made to image the thermal inertia (defined as the square root of the product of thermal conductivity, specific heat and density) of the skin to observe the distribution of blood in the skin during post-occlusive reactive hyperaemia in normal healthy volunteers. The method was based on the ability to calculate thermal inertia by successive thermographic measurements of the skin after stepwise change in ambient radiation temperature surrounding the skin area. The stepwise change was achieved within 0.1 s through a single hood. Experimentation on the undisturbed volar forearm of normal subjects at the same site showed that the measurements thus achieved were reproducible. The thermal inertia values of forearm skin in normal subjects were scattered throughout the range 1.1 x 10(3) to 1.7 x 10(3) W s(1/2) m(-2) K(-1). Experiments on forearm skin subjected to arterial cuff occlusion indicated that thermal inertia can be detected at a low level of blood perfusion. A linear relationship was observed between thermal inertia and blood perfusion measured by laser Doppler imager before and during blood flow occlusion. During reactive hyperaemia, the thermal inertia image exhibited a non-uniform island-shaped pattern of distribution over the forearm, suggesting that, after release from occlusion, recovery of blood flow is non-uniform.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Related Concept Videos
Body Temperature
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...