Inactivation of Cryptosporidium parvum oocysts with ozone and monochloramine at low temperature
A M Driedger1, J L Rennecker, B J Mariñas
1Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, 205 North Mathews Avenue, Urbana, IL 61801, USA.
Abstract:
The rate of Cryptosporidium parvum inactivation decreased with decreasing temperature (1-20 degrees C) for ozone and for monochloramine applied alone as well as after pre-treatment with ozone. Synergy was observed at all temperatures studied for the ozone/monochloramine sequential disinfection scheme. The synergistic effect was found to increase with decreasing temperature. The inactivation rate with monochloramine after ozone pre-treatment was 5 times faster at 20 degrees C and 22 times faster at 1 degree C than the corresponding post-lag phase rates of inactivation with monochloramine at these temperatures when no ozone pre-treatment was applied. The CT required for achieving 2-logs of inactivation ranged from 11,400 mg min l-1 at 20 degrees C to 64,600 mg min l-1 at 1 degree C when monochloramine was applied alone. In contrast, the CT required for an overall sequential inactivation of 2-logs ranged from 721 mg min l-1 at 20 degrees C to 1350 mg min l-1 at 1 degree C when applying monochloramine after ozone pre-treatment. The presence of excess ammonia in the monochloramine solutions was not responsible for the synergy observed in ozone/monochloramine sequential disinfection.
More Related Videos
14:17The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
07:07Controlled-release of Chlorine Dioxide in a Perforated Packaging System to Extend the Storage Life and Improve the Safety of Grape Tomatoes
Published on: April 7, 2017
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Microbial Bioremediation of Pesticides