[Sensor-induced rate adaptation: sensor systems and tuning. Manual versus automatic tuning].

T Lawo1, B Lemke

  • 1Abteilung für Kardiologie und Angiologie, Universitätsklinik Bergmannsheil Bochum. thomas.lawo@ruhr-uni-bochum.de

Herz
|March 22, 2001
PubMed
Summary

Most patients with rate-responsive pacemakers can be managed with automatic sensor adjustment. However, a small group requires manual adjustment, and physicians must verify correct individual rate response for all patients.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Acute bradycardia].

Herzschrittmachertherapie & Elektrophysiologie·2020
Same author

Application of the Bogossian formula for evaluation of the QT interval in pacemaker patients with stimulated left bundle branch block.

Clinical research in cardiology : official journal of the German Cardiac Society·2018
Same author

To implant or not to implant? : That is the unsolved question concerning heart failure patients with non-LBBB.

Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation·2015
Same author

Climate change and occupational health: A South African perspective.

South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde·2015
Same author

Do induced tachycardias within the scope of electrophysiological studies lead to elevated plasma troponin I levels?

Herzschrittmachertherapie & Elektrophysiologie·2011
Same author

Predictors of sustained ventricular arrhythmia episodes in patients with primary ICD indication: male gender and AF in primary ICD prophylaxis.

Herzschrittmachertherapie & Elektrophysiologie·2011

Area of Science:

  • Cardiology
  • Biomedical Engineering

Background:

  • Rate-adaptive cardiac pacing is a standard treatment for heart rhythm disorders.
  • Physiologic heart rate in patients with chronotropic incompetence is achieved through various sensor systems.
  • Complex pacemaker systems with advanced algorithms and closed-loop systems facilitate automatic rate optimization.

Purpose of the Study:

  • To compare automatic versus manual sensor adjustment in rate-responsive pacemakers.
  • To evaluate the effectiveness of automatic sensor adjustment in a broader patient population.

Main Methods:

  • Analysis of patient data to assess automatic sensor adjustment efficacy.
  • Comparison of outcomes between automatic and manual adjustment groups (implied).

Main Results:

Related Experiment Videos

  • Automatic sensor adjustment successfully managed most patients.
  • A small subset of patients required manual adjustment due to technical limitations.

Conclusions:

  • Automatic function is effective for the majority of patients requiring rate-responsive pacing.
  • Physicians must ensure correct individual rate response for all patients, as technical limitations may prevent automatic adjustment in some cases.