Separation of monomethyl-benz[a]anthracene isomers using cyclodextrin-modified electrokinetic chromatography
C Akbay1, S A Shamsi, I M Warner
1Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA.
Abstract:
Cyclodextrin-modified electrokinetic chromatography (CD-EKC) was investigated for the separation of 12 monomethylbenz[a]anthracene (MBA) isomers. Combined use of a polymeric surfactant, poly(sodium 10-undecenyl sulfate) (poly-SUS), with various types of neutral cyclodextrins (CDs) [beta-CD, gamma-CD, dimethyl-beta-CD (DM-beta-CD), trimethyl-beta-CD (TM-beta-CD) and hydroxypropyl-beta-CD (HP-beta-CD)] were successful in CD-EKC separation of the MBA isomers. Baseline resolution of 10 of the 12 isomers, except for 9-MBA and 2-MBA, was achieved with gamma-CD at pH 9.75. The beta-CD, gamma-CD, and beta-CD derivatives (DM-beta-CD, TM-beta-CD, HP-beta-CD) were found to have different resolution and selectivity. Additionally, the tR/t0 values of isomers were found to be dependent on the type and concentration of the CD additives. In general, tR/t0 values of MBA isomers decrease with an increase in the concentration of beta-CD derivatives, whereas the reversed was true when the concentrations of native beta-CD and gamma-CD were varied. The combination of 5 mM gamma-CD, 0.5% (w/v) poly-SUS, 35% (v/v) acetonitrile at a pH of 9.75 provided the best selectivity and resolution of the MBA isomers with a separation time of 110 min. However, the use of 30 mM DM-beta-CD under similar EKC conditions resulted in much faster separation (ca. 16 min) of 10 MBA isomers.
Related Concept Videos
Racemic Mixtures and the Resolution of Enantiomers
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Mass Spectrometry: Cycloalkene Fragmentation
Ion-Exchange Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...