Spontaneous breathing during partial liquid ventilation in animals with meconium aspiration
Related Experiment Video
Updated: Oct 9, 2026

Simplified Whole Body Plethysmography to Characterize Lung Function During Respiratory Melioidosis
Published on: February 24, 2023
H D Hummler1, U Thome, A Schulze
1Division of Neonatology and Pediatric Critical Care, Children's Hospital, University of Ulm, 89070 Ulm, Germany. helmut.hummler@medizin.uni-ulm.de
Abstract:
Partial liquid ventilation (PLV) has been shown to improve gas exchange in paralyzed animals and humans with lung disease. The present study tests the hypothesis that PLV improves gas exchange in spontaneously breathing animals with meconium aspiration supported by proportional assist ventilation. Twenty-five adult anesthetized intubated rabbits with experimental meconium aspiration were randomized to gas ventilation (GV) or PLV while being supported by proportional assist ventilation. Minute ventilation, tidal volume, respiratory rate, mean airway pressure, heart rate, and mean arterial and pulmonary arterial pressure were recorded continuously. Every 30 min, arterial blood gases were obtained, and lung compliance, airway resistance, work of breathing, and cardiac output were measured. Animals were sacrificed after 5 h to obtain lung histology. More PLV animals survived until the end of the study period. PaO(2) (14.5 +/- 4.5 versus 25.6 +/- 6.7 kPa; p < 0.01; GV versus PLV) and lung compliance (4.3 +/- 0.4 versus 6.1 +/- 1.2 mL.kPa(-1).kg(-1); p < 0.001) were improved during PLV, resulting in a lower work of breathing (5.3 +/- 2.8 versus 3.5 +/- 1.5 mL.kPa.kg(-1); p < 0.05) and less need for ventilatory support. Minute ventilation and respiratory rate were higher during GV versus PLV, resulting in a slightly lower PaCO(2) (3.9 +/- 0.5 versus 4.5 +/- 0.7 kPa; p < 0.05). Histologic evaluation showed more atelectasis, inflammatory changes, and hemorrhage in GV animals. Other parameters measured were similar. We conclude that PLV improves oxygenation, lung compliance, and survival and results in less lung injury in spontaneously breathing animals with meconium aspiration when supported by proportional assist ventilation.
Related Concept Videos
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: