Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
[Comparison and reproducibility of 3 indirect methods for measuring blood pressure]
S Widmer1, L M Bachmann, D Holm
1Horten-Zentrum für praxisorientierte Forschung und Wissenstransfer Bolleystrasse 40 Postfach Nord CH-8091 Zürich.
Abstract:
It is rare to find systematic comparisons of various methods for measuring blood pressure. This study aimed to compare blood pressure measurements performed by the doctor, by the patient and on a 24-hour basis with regard to their reliability and reproducibility. A total of 84 patients were included in the study. All patients had their blood pressure measured at the doctor's office twice on day 1 and 10, by themselves and with a 24-h blood pressure measuring unit. The doctors obtained the highest means. The mean systolic and diastolic value taken on the day 1 was higher by 13 mmHg and 8 mmHg than the ABPM value or the measurement obtained by the patient at home, respectively. This difference was still present at the end of the study (7 mmHg and 5 mmHg compared to ABPM and 9 mmHg and 6 mmHg compared to the patient's measurements, respectively). The values obtained by 24-h measurement and the patients themselves showed a better reproducibility than the doctor's measurements. Both methods are thus suitably good for use in diagnostics and therapy monitoring. Compared to the patient's own measurements, the 24-hour blood pressure measurement is less dependent on the patient's reliability.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure