Related Experiment Video
Updated: Jul 27, 2026

DNA Extraction from 0.22 μM Sterivex Filters and Cesium Chloride Density Gradient Centrifugation
Published on: September 18, 2009
Formation of concentration gradient and its application to DNA capillary electrophoresis
1Department of Chemistry, SUNY at Stony Brook, NY 11794-3400, USA.
Abstract:
A new method to introduce the concentration gradient into the capillary has been developed and its application to DNA capillary electrophoresis is presented. The concentration gradient produced by mixing 5% w/v polyacrylamide-co-poly(N-dimethylacrylamide) (PAM-co-PDMA) solution and 1 x Tris/N-tris(hydroxymethyl)methyl-3-amino-propanesulfonic acid/EDTA (TT) + 5 M urea buffer was successfully achieved by using two programmable syringe pumps with strict control of dead volume, flow rate, and pressure balance. This method has the advantages of high stability, reproducibility, and versatility. The column with concentration gradient greatly improved the resolution, especially for the large DNA fragments, due to a decrease in band width broadening with time. A column containing 2-4% w/v gradient in four steps had a longer read length, shorter separation time and better resolution (after 380 base) than that of 4% w/v single concentration polymer solution. The number of steps in the gradient had almost no effect on the performance. The change in the average concentration by relocating the position of the same step gradient, i.e., a combination of different low concentration to high concentration polymer solution ratios, resulted in a different migration time, read length and resolution.
Related Concept Videos
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Ion-Exchange Chromatography
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...

