Measuring temporal variability in residential magnetic field exposures.
W T Kaune1, S Davis, R G Stevens
1EM Factors, Richland, Washington 99352, USA.
Bioelectromagnetics
|April 12, 2001
Summary
New metrics for measuring temporal variability in extremely low frequency (ELF) magnetic fields show promise. First difference and fractional difference metrics accurately capture short-term changes, unlike the RCMS metric.
Area of Science:
- Environmental Health
- Biophysics
- Electromagnetics
Background:
- Growing interest in how organisms respond to temporal variability in extremely low frequency (ELF) magnetic fields.
- Need for reliable methods to quantify temporal variability in magnetic field exposures.
- Previous studies have used various metrics, with unclear interpretations for some.
Purpose of the Study:
- To evaluate five distinct metrics for measuring temporal variability in magnetic field recordings.
- To assess the suitability of these metrics for capturing short-term versus long-term exposure variations.
- To investigate the relationship between these variability metrics and personal/bedroom magnetic field exposures.
Main Methods:
- Theoretical analysis of five variability metrics: D(mean), D(rms), RCMS, F(mean), and F(rms).
- Application of metrics to a dataset of magnetic field recordings from 203 women in Washington State.
- Calculation of Spearman correlations between temporal variability metrics and time-weighted average (TWA) exposures.
Main Results:
- D(mean) and D(rms) metrics are largely unaffected by long-term trends, specifically measuring short-term variability.
- F(mean) and F(rms) also primarily reflect short-term variability.
- The RCMS metric is influenced by both short-term and long-term variability, making its interpretation complex.
- Movement of subjects was the primary source of short-term variability in personal exposures.
- Correlations between TWA exposures and variability metrics were generally low.
- Temporal variability measurements showed weak to moderate consistency over 3-6 month intervals.
Conclusions:
- First difference and fractional difference metrics offer specific and relatively independent measures of short-term magnetic field variability.
- The RCMS metric's lack of clear interpretability for short- or long-term variability raises concerns about its use in prior research.