Local structure and tunneling kinetics of ammonium aluminum alum by infrared hole-burning
1Department of Chemistry, University of California, Berkeley 94720-1460, USA.
Inorganic Chemistry
|April 13, 2001
Abstract:
The title compound, crystallized with a few percent of deuterium, contains some NH(3)D(+) and HOD. At low temperatures, five N-D stretch bands are observed. These belong to two ammonium sites with apparent C(s) symmetry in the low-temperature phase. The N-D bands can be hole-burned with an infrared laser. Burning bands belonging to the A-sites transforms some of them to the higher-energy B-sites. The A- and B-sites probably differ from each other by the arrangement of water and sulfate about the ammonium.
Related Concept Videos
Preparation of Amines: Alkylation of Ammonia and Amines
Alkylation is one of the methods used to prepare amines. Direct alkylation of ammonia or a primary amine with an alkyl halide gives polyalkylated amines along with a quaternary ammonium salt through successive SN2 reactions. This process of making the quaternary salt through the direct alkylation method is called exhaustive alkylation.
Each alkylation step makes the nitrogen center more nucleophilic, which triggers successive alkylations until a quaternary ammonium salt is formed. Considering...
Each alkylation step makes the nitrogen center more nucleophilic, which triggers successive alkylations until a quaternary ammonium salt is formed. Considering...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Absorption Spectroscopy: Lab
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...