Multiple-probe thermography for estimating the postmortem interval: II. Practical versions of the Triple-Exponential
L M Al-Alousi1, R A Anderson, D M Worster
1Department of Forensic Medicine & Science, University of Glasgow, UK.
Abstract:
A simple, reliable, and relatively accurate method for estimating the time since death is described. It is based on the Triple-Exponential Formulae (TEF), which are devised for the first time in this study. The postmortem cooling rate of the brain, liver, and rectum in 117 forensic cases were investigated (Part I). The method can be used in the field as a computer program, reference graph, or reference chart-ruler. The program is simple and can easily be run by any user. There are six reference graphs representing the average brain, liver, and rectal cooling curves for naked and covered body groups. The ruler is designed for the rectal cooling curves for covered and naked bodies. This method requires one temperature measurement of the chosen body site and the environment. The postmortem interval is estimated as a probable value +/- a possible range of time estimates with a built-in confidence limit.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
06:19Standardized Protocol For Monitoring Muscle Fatigue and Biomechanics In Amateur Cyclists Using Infrared Thermography
Published on: March 20, 2026
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
