Evaluation of normal and large sphygmomanometer cuffs using the Omron 705CP
1Department of Primary Health Care, The Medical School, University of Newcastle upon Tyne, UK. malcolm.aylett@smrl.demon.co.uk
Abstract:
Sphygmomanometers are usually sold with a single cuff though some are supplied with a short cuff as standard and offer a longer one for larger arms. However, data on the differences in measurements taken with different cuffs applied to different sized arms are conflicting and this study set out to investigate the difference between those taken with 'normal' and 'large' cuffs in arms 28 cm or more in circumference. We avoided observer error by using a semi-automatic digital sphygmomanometer, the Omron 705CP. The 22 subjects employed were selected from one general practice as having a range of previous office blood pressures and a variety of arm sizes above 28 cm in circumference. Omron 'normal' and 'large' cuffs were used alternately, taking five blood pressures with each to a total of 30 readings per patient, resulting in 660 readings, 330 with each cuff. There were mean systolic/diastolic differences of 2.7/3.8 (s.d.s 4.7/2.8) for all subjects. These were greater in the normotensive. When divided into two groups with systolic blood pressures below and equal to or above 140 mm Hg, differences were -1.9/3.0 to 7.1/4.7. From the results of the study, we recommend that large cuffs should be used for all patients with an arm circumference of 28 cm or above but the Omron large cuff still requires formal validation.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...