Determination of heavy metal contents in human colostrum samples by electrothermal atomic absorption

S Turan1, S Saygi, Z Kiliç

  • 1Department of Analytical Toxicology, GATA, Etlik, Ankara, Turkey.

Determination of lead, cadmium, nickel, chromium, manganese and copper levels in colostrum samples (n = 30), collected from middle-class mothers, was carried out by electrothermal atomic absorption spectrophotometer (ETAAS) with Zeeman effect background correction using a tungsten-palladium-citric acid chemical modifier mixture. A wet-ashing procedure was applied to dissolve the samples and to remove the fat. The graphite furnace temperature programme for analytes determined by ETAAS was studied, and the optimum pyrolysis temperatures of Pb, Cd, Ni, Cr, Mn and Cu were determined in the presence of the modifier mixture. Detection limits of Pb, Cd, Cu, Mn and Cr were determined using a modifier mixture solution. Zinc and iron levels were determined by Zeeman flame atomic absorption spectrometer (F-AAS). Heavy metal levels (mean values) found in colostrum samples were 14.6 microg/l of Pb, 2.8 microg/l of Cd, 27.8 microg/l of Ni, 8.6 microg/l of Cr, 43.2 microg/l of Mn, 278 microg/l of Cu, 12.9 mg/l of Zn, and 3.5 mg/l of Fe. These metal levels were compared with results from other studies in different countries.

Related Concept Videos

Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...