[Prevention of nosocomial infection during nebulization and spirometry]
1Service de pneumologie, Groupe hospitalier Pitié-Salpêtrière, 75651 Paris Cedex 13.
Abstract:
The nebulizer, designed for the delivery of important quantities of drugs to the bronchi and lungs can also deliver microbial deposits. The risk can be one of recontaminating a patient with his/her own bacteria, contaminating other individuals (other patients or staff during a nebulization session from a patient infected by an ordinary germ or tuberculosis), or transmission via unclean equipment, contaminated water or medicines. The use of single-dose drug preparations, single-patient devices, sterile water, and rigorous applications of the protocols can considerably reduce the risk. Although respiratory function tests are done with expensive equipment that has to be reused, sometimes by a large number of patients in the same day, cases of cross-contamination are exceptional. Closed spirometers are however a risk. The use of single-use filters can save money and time needed to clean all the device parts used in connection with the inspiratory circuit during respiratory tests. In intensive care units, the passage of spirometers from one patient to the next without a cleaning procedure is a situation of risk. In all these situations, implementation of cleaning protocols allows to reduce this risk, although zero risk cannot be achieved especially for recontamination of patients by their own bacteria during nebulization.
Insights
Nebulizers and spirometers can transmit microbes, risking patient and staff contamination. Strict cleaning protocols and single-use items significantly reduce, but cannot eliminate, this risk.
Area of Science:
- Medical device safety
- Infection control in healthcare settings
Context:
- Nebulizers deliver medications to the lungs but can aerosolize microbial deposits.
- Respiratory equipment, including spirometers, poses cross-contamination risks, especially in intensive care units.
Purpose:
- To highlight the microbial transmission risks associated with nebulizers and respiratory equipment.
- To outline strategies for mitigating infection transmission during medical procedures.
Summary:
- Microbial contamination can occur via nebulizers (recontamination, cross-contamination) and reused respiratory devices like spirometers.
- Implementing single-dose preparations, single-patient devices, sterile water, and rigorous cleaning protocols minimizes contamination risks.
- While zero risk is unattainable, especially for autoinfection during nebulization, adherence to protocols is crucial.
Impact:
- Enhanced patient safety through reduced healthcare-associated infections.
- Improved infection control practices in respiratory care and intensive care settings.
- Guidance for healthcare professionals on minimizing microbial transmission risks with medical equipment.
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed.
Inhaled Medications
Suctioning the Nasopharyngeal Airway
Equipment Required