High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Capillary ion electrophoresis of endogenous anions and anionic adulterants in human urine
K E Ferslew1, A N Hagardorn, T A Robert
1Department of Pharmacology, James H. Quillen College of Medicine, East Tennessee State University, Johnson City 37614-0422, USA.
Abstract:
Normal human urine contains many anions and cations. Ionic concentrations in urine have classically been determined by spectrophotometry of color reactions, flame emission spectrophotometry, atomic absorption spectrophotometry, high performance liquid chromatography, or potentiometry with ion-specific electrodes. Capillary ion electrophoresis (CIE) is a form of capillary electrophoresis which uses the differential electrophoretic mobility of ions to perform a separation of an ionic mixture. Various salts can be added to urine specimens to abnormally elevate ionic concentrations and interfere with either immunoassay urine drug screening procedures or gas chromatographic/mass spectrometric confirmation techniques. Application of CIE for the direct detection of endogenous anions and anionic adulterants in human urine specimens was the purpose of this investigation. CIE was performed using a Waters Quanta 4000 Capillary Electrophoresis System with either direct or indirect ultraviolet absorption detection at 254 nm. CIE of 30 random normal urine specimens and 21 urine specimens suspected of adulteration was performed. Duplicate aliquots were assayed by CIE and by colorimetric technique for nitrite. Sixteen specimens had elevated concentrations of nitrite and/or nitrate. The correlation coefficient between nitrite CIE and colorimetric results was 0.9895. Three specimens had detectable concentrations of chromate and were suspected of being adulterated with "Urine Luck," an adulterant found to contain chromate. Two specimens suspected of being adulterated with bleach were found to only contain chloride, sulfate, and phosphate. CIE is applicable to forensic analysis of urine anion concentrations. CIE can easily quantitate numerous endogenous anions and offers a method to detect and/or confirm anion adulteration of urine specimens.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Related Concept Videos
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Urine Studies I: Urinalysis
Physiology of the Genitourinary System III: Urine Concentration and Dilution