Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy
R Waugh1, H M McCallum, M McCarty
1Division of Radiology, South Cleveland Hospital, South Tees Acute Hospitals NHS Trust, Marton Road, Middlesbrough, Cleveland T54 3BW, UK.
Grid-controlled fluoroscopy (GCF) significantly reduces radiation dose in paediatric pelvic radiography. Frame grab images offer comparable clinical quality to digital spot images (DSI) with even lower radiation exposure.
Area of Science:
- Radiology
- Paediatric Imaging
- Radiation Dose Reduction
Background:
- Paediatric pelvic radiographs revealed issues with gonad shielding and technique.
- Perthes disease and Developmental Hip Dysplasia (DDH) require regular pelvic radiography in children.
Purpose of the Study:
- To evaluate grid-controlled fluoroscopy (GCF) for optimizing gonad shield placement and reducing radiation dose.
- To compare frame grab and digital spot image (DSI) formats in paediatric pelvic radiography.
Main Methods:
- Conducted phantom and patient dose surveys comparing conventional and fluoroscopic techniques.
- Assessed image quality and radiation dose for frame grab and DSI.
- Performed retrospective evaluation of clinical acceptability.
Main Results:
- Fluoroscopic techniques reduced radiation by 67-83% compared to conventional radiography (P < 0.05).
- Frame grab technique yielded lower radiation doses than DSI (P < 0.05).
- No significant difference in clinical acceptability between DSI and frame grab images.
Conclusions:
- Fluoroscopy-acquired images are now standard due to lower dose and sufficient quality.
- Frame grab alone will be adopted for further dose savings, as it matches DSI's clinical usefulness.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
07:43In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies II: Ultrasonography
Imaging Studies III: Computed Tomography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies VII: Vascular Imaging