Conductivity detection cell for capillary zone electrophoresis with a solution mediated contact of the separated
R Bodor1, D Kaniansky, M Masár
1Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University, Bratislava, Slovak Republic.
Abstract:
A contact conductivity detection cell for capillary zone electrophoresis (CZE) with an electrolyte solution mediated contact of the separated constituents with the detection electrodes (ESMC cell) was developed in this work. This new approach to the conductivity sensing in CZE is intended to eliminate detection disturbances due to electrode reactions and adsorption of the separated constituents when these are coming into direct contact with the detection electrodes. An optimum detection performance of the cell was achieved when the carrier electrolyte solution mediated the electric contact of the detection electrodes with the separated constituents. Different compositions of the mediator and carrier electrolyte solutions led to large drifts of the detection signals. Isotachophoresis experiments performed in this context with the ESMC cell revealed that origins of these drifts are in transport processes (diffusion and electromigration) between the detection compartment and the detection electrodes in the cell. These processes affected, to some extent, other analytically relevant performance parameters of the ESMC cell of the present construction as well [e.g., concentration limits of detection (LODs), a contribution of the cell to the band broadening]. For example, the ESMC cell gave, under optimum operating conditions, 3-4 times higher concentration LODs for the test analytes than a current on-column conductivity cell employed under identical working conditions. On the other hand, these LOD values (25-150 nmol/l) were still 20-25 times lower than those estimated from reference experiments for a contactless conductivity detector. CZE experiments with iodide, carried out under working conditions leading to electrochemical reactions of this anion on the detection electrodes of current conductivity cells, did not occur in the ESMC cell. In addition, this cell, contrary to a reference contact conductivity cell, required no special care (e.g., cleaning of the surfaces of the detection electrodes by chemical or electrochemical means) to maintain its reliable long-term performance. Anionic CZE analyses of tap and mineral water samples monitored by the conductivity detector provided with the ESMC cell demonstrated a practical applicability and certain limitations of this detection approach in the analysis of ionic constituents present in high ionic strength sample matrices.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Ion-Exchange Chromatography
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...