Bioelectrical impedance analysis estimation of water compartments in elderly diseased patients: the source study
P Ritz1,
1Centre Hospitalier Universitaire, Angers, France. patrick.ritz@wanadoo.fr
Background:
This study validates, in geriatric patients, bioelectrical impedance analysis (BIA) equations that had been derived to estimate total body water (TBW) and extracellular water (ECW) in healthy elderly subjects.
Methods:
We performed a multicentric trial in six geriatric wards. We studied 169 patients with varying degrees of hydration: dehydrated, euvolemic, and overhydrated. BIA estimates of TBW and of ECW were compared with the measurement of TBW with (18)O dilution and of ECW with bromide (Br) dilution.
Results:
BIA estimated TBW with a difference of 0.48 +/- 2.3 l (mean +/- SD) (50 kHz; p = .01) and 0.69 +/- 2.2 l (100 kHz; p < 0.001) compared with (18)O dilution. The difference was not affected by the hydration status. Estimates of ECW with BIA were systematically biased compared with Br dilution: 4.6 +/- 3.1 l (equation from Segal and colleagues; p < .001) and 3.4 +/- 2.9 l (equation from Visser and colleagues; p < .001). We propose a new, cross-validated equation. Conclusions. Body water spaces can be estimated accurately in geriatric patients with BIA.
Related Concept Videos
Pharmacokinetics in Geriatric Patients: Effect of Age on Drug Excretion
Bode Plots Construction