Related Experiment Video
Updated: Oct 7, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Visualization of solute migration in chromatographic columns influence of the frit porosity
B S Broyles1, R A Shalliker, G Guiochon
1Department of Chemistry, The University of Tennessee, Knoxville 37996-1600, USA.
Abstract:
The dual-perspective, on-column detection method previously described was used to observe the effects of the inlet frit on the profiles of chromatographic bands. Visualization of bands of iodine was achieved by injecting its dilute solutions in carbon tetrachloride into a glass column packed with a C18-bonded silica and eluted with carbon tetrachloride, which has the same refractive index as the packing material. The bands were photographed on-column with two standard 35-mm SLR cameras oriented at right angle. The photographs were scanned and the digitized images of the sample bands analyzed with proper software. A number of columns, as similar as possible, were fitted with different 2- and 10-microm porosity stainless steel frits. Subsequent analysis of the digitized band images revealed irregularities in the band shape resulting from frit contributions to band dispersion. The 2-microm frits produced more dramatic effects overall than the coarser frits. Local axial dispersion coefficient values, expressed as local reduced plate height, were calculated. The results demonstrate the possibly damaging effects of the frit on the band shape.
Related Concept Videos
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Principles Of Column Chromatography
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...