Related Experiment Video
Updated: Jul 24, 2026

Intrauterine Telemetry to Measure Mouse Contractile Pressure In Vivo
Published on: April 6, 2015
A new device for measuring intrauterine temperature.
A C Sciscione1, T Zainia, T Leet
1Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Christiana Care Health Services, Newark, Delaware, USA.
A new intrauterine pressure-temperature catheter accurately measures maternal labor temperature. This device offers a convenient method for continuous uterine temperature monitoring during labor.
Area of Science:
- Medical Devices
- Obstetrics and Gynecology
- Maternal-Fetal Medicine
Background:
- Accurate maternal temperature monitoring is crucial during labor.
- Existing methods may have limitations in continuous or intrauterine assessment.
- Intrauterine pressure catheters are commonly used in labor monitoring.
Purpose of the Study:
- To evaluate a novel device for measuring maternal temperature using an intrauterine pressure catheter.
- To assess the accuracy and convenience of continuous intrauterine temperature measurement during labor.
Main Methods:
- A prospective study involving 97 laboring patients at two medical centers.
- Simultaneous intrauterine, oral, and tympanic temperature readings were obtained.
- An intrauterine pressure catheter with a thermistor sensor was utilized.
Main Results:
- A total of 404 temperature readings were collected.
- A linear relationship was observed between intrauterine, oral, and tympanic temperatures.
- All methods showed a significant temperature increase post-epidural anesthesia.
Conclusions:
- The intrauterine pressure-temperature catheter provides a convenient and accurate method for continuous uterine temperature monitoring.
- This device is suitable for laboring patients requiring intrauterine monitoring.
- The findings support the utility of this integrated device in obstetric care.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...