Related Experiment Video
Updated: Mar 23, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
An analogue instrument for the measurement of respiratory impedance using the forced oscillation technique
1Clinical Physics Group, Barts, London NHS Trust, Royal London Hospital, London E1 1BB, UK. m.j.birch@mds.qmw.ac.uk
Abstract:
The successful development of non-invasive assisted ventilation via a nasal mask has led to the requirement for improved methods of monitoring the respiratory system. Measurements of respiratory impedance during assisted ventilation using acoustic methods are showing considerable promise in providing this clinical data. The method involves imposing very low amplitude acoustic oscillations onto the spontaneous or assisted respiratory airflow. The subsequent interaction with the respiratory system modifies the pressure and flow relationship of the forced oscillations. The ratio of pressure to flow can be used to measure in real time the absolute value of respiratory input impedance. As a result a versatile, non-invasive and repeatable profile of respiratory mechanics is obtained. Using a 5 Hz conventional forced oscillation frequency, data highly sensitive to airflow obstruction and capable of tracking mechanical events and responses become available to the clinician. Recent studies with ventilated and sleeping subjects confirm future potential for the forced oscillation technique in vivo. We describe an instrument named the respiratory impedance monitor (5 Hz), which utilizes the forced oscillation technique (FOT). This fully developed device is designed in accordance with agreed international clinical guidelines. Comparative clinical data from normal subjects and patients with chronic obstructive pulmonary disease is presented.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...

