Related Experiment Video
Updated: Aug 14, 2026

Method and Instrumented Fixture for Femoral Fracture Testing in a Sideways Fall-on-the-Hip Position
Published on: August 17, 2017
Experimental investigation of failure load and fracture patterns of C2 (axis)
1School of Mechanical and Production Engineering, Nanyang Technological University, Nanyang Ave, 639798, Singapore. mecto@ntu.edu.sg
Abstract:
The injury mechanism and magnitude of failure load of C2 fractures are important in the clinical treatment of its fixation. The magnitudes of the failure load of C2 and the mechanism of injury in vivo are uncertain. Accordingly, nine C2 vertebrae obtained from cadaver spines, ranging in age from 51 to 80 years, were used for the study. Special restraint conditions were applied to yield specific fracture of C2. With the posterior element potted postero-anteriorly up to one-quarter of the inferior facet, posterior shear force ranging from 840 to 1220N was required to cause fracture across the pars interarticularis. For odontoid fracture study, a special rig was fabricated to encapsulate the body of C2 in a cell using ISOPON, and a thin layer of ISOPON sandwiched between the inferior facets and two lateral plates. The assembled rig permits slight sagittal movement of C2 about the cup lateral pivot supports. Failure load of between 900 and 1500N was recorded for odontoid fracture. These values are in agreement with published data. The experiment carried out under these two different restraint conditions had specifically resulted in different fractures of C2. In reality, depending on factors such as the inclination of this force vector applied to the head, the precise posture at the time of trauma, the spinal geometry, and the physical properties, different types of fracture patterns of C2 may be produced. This additional data will be useful in the biomechanical study of C2 vertebra using analytical approaches, and in surgical anterior/posterior fixation using screws.
Related Concept Videos
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes.
Normal Strain under Axial Loading
Fatigue
Eccentric Axial Loading in a Plane of Symmetry
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical bending,...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...

