Related Experiment Videos
[Study on the noninvasive measurement of cerebral oxygen saturation and cerebral phronetal function]
1Dept. of Precision Machinery & Precision Instrumentation, University of Science & Technology of China, Hefei 230026.
Abstract:
With the use of Near-infrared spectroscopy(NIRS), the noninvasive measurement of cerebral oxygen concentration can be achieved in vivo based on the Lambert-Beer Law. In this paper, we discuss the possibility of studying higher brain functions through a combination of cerebral oxygen saturation and cerebral function measurement. Event-related experiments are introduced to measure the cerebral phronetal function. Time domain curves show sight differences among these experiment results. However, with the aid of DFT, experiment data of all five human volunteers show that the frequency near 20 Hz or 40 Hz is evoked depending on the difficulty of the mental tasks. The results demonstrate the feasibility of cerebral function studies by means of cerebral oxygen saturation measurement analysis in the frequency domain.