Related Experiment Video
Updated: Aug 9, 2026
![Protein Film Infrared Electrochemistry Demonstrated for Study of H2 Oxidation by a [NiFe] Hydrogenase](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F55858.jpg&w=3840&q=50)
Protein Film Infrared Electrochemistry Demonstrated for Study of H2 Oxidation by a [NiFe] Hydrogenase
Published on: December 4, 2017
Influence of gamma irradiation on a natural source of peroxidase and its effect in the reagentless amperometric
M P Sotomayor1, I Facchin, G O Neto
1Instituto de Química, UNICAMP, PO Box 6154 13083-970, Campinas, SP, Brazil.
Abstract:
Peroxidase was extracted from a natural source (turnip) and irradiated with 60Co (0.1 kGy). It was then used in the construction of biosensors for hydrogen peroxide determination, in order to study the effect of the gamma irradiation on the performance of the biosensors. The biosensors were constructed using two immobilization procedures: cross-linking with glutaraldehyde and covalent binding through carbodiimide. The biosensor prepared using covalent binding through carbodiimide showed a higher sensitivity for H2O2. A good enhancement in stability and sensitivity was obtained for the biosensors from irradiated material, when compared to biosensors prepared with non-irradiated enzyme. However, the initial linear response range (1.0 to 10.0 mmol dm-3) and response time (0.5 s) were equal with or without irradiation.
Related Concept Videos
Catalysis
Regioselectivity of Electrophilic Additions-Peroxide Effect
Peroxisomes
Amperometry: Overview